Browse content of UTPedia using Year, Subject, Department and Author and Search for required document using Searching facilities included in UTPedia. UTPedia with full text are accessible for all registered users, whereas only the physical information and metadata can be retrieved by public users. UTPedia collaborating and connecting peoples with university’s intellectual works from anywhere.

Disclaimer - Universiti Teknologi PETRONAS shall not be liable for any loss or damage caused by the usage of any information obtained from this web site.Best viewed using Mozilla Firefox 3 or IE 7 with resolution 1024 x 768.

MONITORING UNDERGROUND CABLE CONDITION UTILIZING THIRD HARMONIC CURRENT

Mohd Yusof, Mohd Asnawi (2014) MONITORING UNDERGROUND CABLE CONDITION UTILIZING THIRD HARMONIC CURRENT. Universiti Teknologi Petronas. (Unpublished)

[img]
Preview
PDF
Download (1869Kb) | Preview

Abstract

Power failure in a power system caused by unscheduled cable failure may give significant problem to the utility company and to the consumers. This unscheduled cable failure can be overcame by periodically monitor the cable condition. There are many ways to monitor cable condition such as visual inspection, infrared thermography, ultrasound, insulation resistance and others. Third harmonic in triplen harmonics may also be used to monitor cable condition. Lab experiments have been conducted to investigate the relationship of third harmonic voltage and current passing various cable conditions that specifically affected by their insulation. The objective of this research is to study the applicability of using third harmonic to monitor cable condition. Preliminary research is done to collect necessity information and vigorous lab with different loads is initiated to achieve the objective. Further discussion is made to come out with a conclusion of the project and recommended steps are listed for future development. The results show a significant existence of third harmonic voltage and current at the phase line and the value at the neutral line is three times from the phase line. Connection of transformer (delta-wye) will only circulate the third harmonic current at delta connection from flowing continuously into the wye connection and the load. The third harmonic flows through a capacitor significantly at a range value of 1uF to 2uF.

Item Type: Final Year Project
Academic Subject : Academic Department - Electrical And Electronics - Pervasisve Systems - Digital Electronics - Design
Subject: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Engineering > Electrical and Electronic