Browse content of UTPedia using Year, Subject, Department and Author and Search for required document using Searching facilities included in UTPedia. UTPedia with full text are accessible for all registered users, whereas only the physical information and metadata can be retrieved by public users. UTPedia collaborating and connecting peoples with university’s intellectual works from anywhere.

Disclaimer - Universiti Teknologi PETRONAS shall not be liable for any loss or damage caused by the usage of any information obtained from this web site.Best viewed using Mozilla Firefox 3 or IE 7 with resolution 1024 x 768.

Prediction of Evaporator Performance of Double Effect Steam Absorption Chiller

Noor Azman, Muhammad Aiman Faris (2018) Prediction of Evaporator Performance of Double Effect Steam Absorption Chiller. UNSPECIFIED.

[img] PDF
Restricted to Registered users only

Download (953Kb)

Abstract

Generation of chilled water mostly done using absorption chillers in cooling plant. The application of double effect type chillers are normally be used as it can offer high efficiency compared to single-effect chillers. The COP double-type varies between 0.7 to 1.3. The relation of internal heat input could give effect to the COP of the chillers. This study was related to the evaluating COP changes with increasing of evaporator performance by using internal operating condition of double effect steam absorption chiller. Operating data for 61 days were used for the study. Duhring double effect schematic diagram was used for developing mass and energy balance equations. Results demonstrated actual COPs were between 1.3 to 1.5 and trends increased simultaneously to the incremental of evaporator performance. From COP outcomes obtained, the results were found to be within the range of COP from other researchers. Due to uncertainty in chiller machine performance, it is recommended to perform economic analysis so that decision can be made whether to replace or keep up the existing absorption chiller.

Item Type: Final Year Project
Academic Subject : Academic Department - Mechanical Engineering - Petroleum
Subject: UNSPECIFIED
Divisions: Engineering > Mechanical
Depositing User: Ahmad Suhairi Mohamed Lazim
Date Deposited: 20 Jun 2019 08:19
Last Modified: 20 Jun 2019 08:19
URI: http://utpedia.utp.edu.my/id/eprint/19268

Actions (login required)

View Item View Item

Document Downloads

More statistics for this item...