Browse content of UTPedia using Year, Subject, Department and Author and Search for required document using Searching facilities included in UTPedia. UTPedia with full text are accessible for all registered users, whereas only the physical information and metadata can be retrieved by public users. UTPedia collaborating and connecting peoples with university’s intellectual works from anywhere.

Disclaimer - Universiti Teknologi PETRONAS shall not be liable for any loss or damage caused by the usage of any information obtained from this web site.Best viewed using Mozilla Firefox 3 or IE 7 with resolution 1024 x 768.

STUDIES ON COMPARISON OF PROPORTIONAL ON ERROR WITH PROPORTIONAL ON MEASURED VALUE IN PID CONTROLLERS

WAN MOHD RUSHIDI, WAN AMIR HAKIMI (2019) STUDIES ON COMPARISON OF PROPORTIONAL ON ERROR WITH PROPORTIONAL ON MEASURED VALUE IN PID CONTROLLERS. IRC, Universiti Teknologi PETRONAS. (Submitted)

[img] PDF
Restricted to Registered users only

Download (2141Kb)

Abstract

PID Controllers have different algorithms or methods in which the controller action is based on Error or Process Variable (PV). In this paper, it covers about the effect of time delay towards the behaviour of the controller as well as seeing how, the different algorithms of PID, specifically with Proportional Action based on Error and Proportional Action based on PV affects the controller behaviour towards setpoint (SP) changes and Disturbance or Load Changes. Usually, it is addressed as an I–PD controller because only integral action acted on error but for this paper, it will be focusing on ID–P controller when basing the proportional action on PV. The method to test these is using the software MATLAB, specifically Simulink. Based on the findings, Proportional on PV algorithm responds slower than Proportional on Error algorithm. Though, by increasing the value of Kc can improve the response for Proportional on PV algorithm to make it as having similar response with Proportional on Error algorithm that uses the original Kc. As a conclusion, time delay postpones the response of the controller while using the Proportional on PV removes proportional kick in the controller response.

Item Type: Final Year Project
Academic Subject : Academic Department - Chemical Engineering - Advance Process Control
Subject: UNSPECIFIED
Divisions: Engineering > Chemical
Depositing User: Ahmad Suhairi Mohamed Lazim
Date Deposited: 13 Dec 2019 09:18
Last Modified: 13 Dec 2019 09:18
URI: http://utpedia.utp.edu.my/id/eprint/20051