Browse content of UTPedia using Year, Subject, Department and Author and Search for required document using Searching facilities included in UTPedia. UTPedia with full text are accessible for all registered users, whereas only the physical information and metadata can be retrieved by public users. UTPedia collaborating and connecting peoples with university’s intellectual works from anywhere.

Disclaimer - Universiti Teknologi PETRONAS shall not be liable for any loss or damage caused by the usage of any information obtained from this web site.Best viewed using Mozilla Firefox 3 or IE 7 with resolution 1024 x 768.

EVALUATION THE PERFORMANCE OF VARIOUS PARAMETERS USED TO CHARACTERIZE WASTEWATER FOR UTP SEWAGE TREATMENT PLANT & UTP OXIDATION POND

AZMI, NORAZHAM (2004) EVALUATION THE PERFORMANCE OF VARIOUS PARAMETERS USED TO CHARACTERIZE WASTEWATER FOR UTP SEWAGE TREATMENT PLANT & UTP OXIDATION POND. Universiti Teknologi Petronas. (Unpublished)

[img] PDF
Download (2147Kb)

Abstract

This report is a study for evaluation the performance of various parameters usedto characterize wastewater for UTP Sewage Treatment Plant and UTP oxidation pond. University Technology Petronas Sewage Treatment Plant (UTP's STP) is a treatment plant that used an Extended Aeration Activated Sludge (EEAS). The sewage treatment plant is capableto treat effluent to a standard A which is 20mg/l of BOD and 50mg/l of suspended solids. A hydraulic loading off225 I/pe/dand an organic loading off 55 g/pe/dand sludge storage of 40 days at 4% of solid were condered for design. The design basis flow rate for this plant is about 5,175.00 m3/d or 23,000 population equivalent. This sewage treatment plant consists of inlet chamber, grit and grease chamber, distribution chamber, anoxic zone, aeration tank, clarifier and chlorination tank. UTP oxidation pond was designed to support 2000 populations from UTP and classified as a facultative pond which the stabilization ofwastewater is done by a combination of aerobic, anaerobic and facultative bacteria. The influent of wastewater that enters to the pond is assumed consisted of 250 mg/1 BODand 300 mg/1 of total suspended solids (TSS). Thetreated effluent for this oxidation pond should meet the standard A limit which is 20 mg/1 of BOD and 50 mg/1 of total suspended solid. This UTPoxidationpond contains a rubbish trap chamber, parshall flume chamber, scum chamber, oxidation pond and settling pond. At the beginning stage, the problems are identified on the various parameters such like biochemical oxygen demand (BOD) and total suspended solids (TSS). Samples from UTP's STP and oxidation pond was taken and identified frequently to analyzethe wastewater in the laboratory. The sample was taken by using grab and composite sampling method at the influent and effluent ofthe UTP's STP and UTP oxidation pond.

Item Type: Final Year Project
Academic Subject : Academic Department - Civil Engineering - Water and environment - Environmental - Wastewater treatment
Subject: T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Engineering > Civil