Browse content of UTPedia using Year, Subject, Department and Author and Search for required document using Searching facilities included in UTPedia. UTPedia with full text are accessible for all registered users, whereas only the physical information and metadata can be retrieved by public users. UTPedia collaborating and connecting peoples with university’s intellectual works from anywhere.

Disclaimer - Universiti Teknologi PETRONAS shall not be liable for any loss or damage caused by the usage of any information obtained from this web site.Best viewed using Mozilla Firefox 3 or IE 7 with resolution 1024 x 768.

Segmentation of Retinal Vasculature using Active Contour Models (Snakes)

Pang, Kee Y ong (2009) Segmentation of Retinal Vasculature using Active Contour Models (Snakes). Universiti Teknologi Petronas. (Unpublished)

[img] PDF
Download (6Mb)

Abstract

Characteristic of retinal vasculature has been an important indicator for many diseases such as hypertension and diabetes. A digital image analysis system can assist medical experts to make accurate diagnosis in an efficient manner. This project presents the computer based approach to the automated segmentation of blood vessels in retinal images. The detection of the retinal vessel is achieved by performing image enhancement using CLAHE followed by Bottom-hat morphological transformation. Active contour model (snake) that based on level sets, techniques of curve evolution, and Mumford-Shah functional for segmentation is then used to segment out the detected retinal vessel and produce a complete retinal vasculature. A Graphic User Interface (GUI) has also been created to ease the user for the segmentation of the retinal vasculature. The algorithm is then tested with 20 test images from the DRIVE database. The results shows that the algorithm outperforms many other published methods and achieved an accuracy (ability to detect both vessel and non-vessel pixels) range of 0.92-0.94, a sensitivity (ability to detect vessel pixels) range of 0.91-0.95 and a specificity (ability to detect non-vessel pixels) range of0.78-0.85. IV

Item Type: Final Year Project
Academic Subject : Academic Department - Electrical And Electronics - Pervasisve Systems - Digital Electronics - Test and Reliablity
Subject: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Engineering > Electrical and Electronic
Depositing User: Users 2053 not found.
Date Deposited: 22 Oct 2013 09:11
Last Modified: 25 Jan 2017 09:44
URI: http://utpedia.utp.edu.my/id/eprint/8926