Browse content of UTPedia using Year, Subject, Department and Author and Search for required document using Searching facilities included in UTPedia. UTPedia with full text are accessible for all registered users, whereas only the physical information and metadata can be retrieved by public users. UTPedia collaborating and connecting peoples with university’s intellectual works from anywhere.

Disclaimer - Universiti Teknologi PETRONAS shall not be liable for any loss or damage caused by the usage of any information obtained from this web site.Best viewed using Mozilla Firefox 3 or IE 7 with resolution 1024 x 768.

Evaluation of Effect Of Operating Temperature To Corrosion under Insulation (CUI)

Ismail, Muhammad Hafiz (2014) Evaluation of Effect Of Operating Temperature To Corrosion under Insulation (CUI). Universiti Teknologi PETRONAS. (Unpublished)

[img]
Preview
PDF
Download (1005Kb) | Preview

Abstract

Corrosion under insulation (CUI) is a major common problem shared by all of the refining, power, industrial, petrochemical, onshore and offshore industries on a worldwide scale. CUI is a form of localized external corrosion that occurs in carbon manganese, low alloy, and austenitic stainless steel piping and vessels that occurs underneath externally clad /jacketed insulation due to the penetration of water[1]. The majority of CUI occurrences reported are between the -4°C and 175°C (25°F and 347°F). This research is done to study the relationship between operating temperature and corrosion rate due to CUI. A laboratory cell was setup according to ASTM G189-07 for the simulation of CUI. The CUI cell consisted of six carbon steel ring specimens separated by insulated spacers and held together by blind flanged pipe sections on both ends. Thermal insulation which was placed around the testing section provided the annular space to retain the solution which represents the test environment. The ring specimens were used to test electrodes in two separate electrochemical cells. Corrosion measurements were made using both electrochemical polarization resistances and mass loss data under isothermal test conditions. The corrosion rate at higher operating temperature (121°C) was found to be higher compared to corrosion rate at lower operating temperature (65°C).

Item Type: Final Year Project
Academic Subject : Academic Department - Mechanical Engineering - Materials - Engineering materials - Metals alloys - Fabrication
Subject: T Technology > TJ Mechanical engineering and machinery
Divisions: Engineering > Mechanical