Browse content of UTPedia using Year, Subject, Department and Author and Search for required document using Searching facilities included in UTPedia. UTPedia with full text are accessible for all registered users, whereas only the physical information and metadata can be retrieved by public users. UTPedia collaborating and connecting peoples with university’s intellectual works from anywhere.

Disclaimer - Universiti Teknologi PETRONAS shall not be liable for any loss or damage caused by the usage of any information obtained from this web site.Best viewed using Mozilla Firefox 3 or IE 7 with resolution 1024 x 768.

The Effects Of Applied Potential And Coating Thickness On Cathodic Disbondment Of Polyurea Coating

Abdul Halim bin Razak , Abdul Halim (2010) The Effects Of Applied Potential And Coating Thickness On Cathodic Disbondment Of Polyurea Coating. Universiti Teknologi Petronas. (Unpublished)

[img]
Preview
PDF
Download (2735Kb) | Preview

Abstract

Cathodic disbondment of buried pipelines is a serious threat to the integrity of the corrosion protection system of the pipelines. This project investigates the effects of applied potential and coating thickness to cathodic disbondment of polyurea coating. The objectives of this project are to determine suitable applied potential of cathodic protection and dry film thickness that will not cause cathodic disbondment. The investigation involved two cathodic protection experiments. For the first experiment, four samples with 1.5 mm coating thickness were used and each of them were exposed to different applied potential which varied from -600 mV to -1500 mV. For the second experiment, four samples having 1.0 mm, 1.5 mm, 2.0 mm and 2.5 mm coating thickness were used and the same applied potential of -850 mV were used. Result from the experiments show that at coating thickness of 1.5mm, -850 mV is the best applied potential for cathodic protection that can avoid cathodic disbondment. When -1500 mV applied potential is used, it causes a lot of cathodic disbondment effects. Then, at -850 mV applied potential, 1.5 mm is the optimum coating thickness that can reduce cathodic disbondment effects. When the coating thickness increases more than 1.5 mm, cathodic disbondment effects are also increase. Besides that, absorption of water also increases as the coating thickness increases. In conclusion, an applied potential of -850 mV and a coating thickness of 1.5 mm was found able to reduce cathodic disbondment effects.

Item Type: Final Year Project
Subject: T Technology > TJ Mechanical engineering and machinery
Divisions: Engineering > Mechanical
Depositing User: Users 5 not found.
Date Deposited: 11 Jan 2012 12:23
Last Modified: 25 Jan 2017 09:43