Browse content of UTPedia using Year, Subject, Department and Author and Search for required document using Searching facilities included in UTPedia. UTPedia with full text are accessible for all registered users, whereas only the physical information and metadata can be retrieved by public users. UTPedia collaborating and connecting peoples with university’s intellectual works from anywhere.

Disclaimer - Universiti Teknologi PETRONAS shall not be liable for any loss or damage caused by the usage of any information obtained from this web site.Best viewed using Mozilla Firefox 3 or IE 7 with resolution 1024 x 768.

Study Of A Backup Ve_Tilatio_ System For Lecturers’ Office Space

Muhammad Zahid bin Md Bahari, Muhammad Zahid (2010) Study Of A Backup Ve_Tilatio_ System For Lecturers’ Office Space. Universiti Teknologi Petronas. (Unpublished)

[img]
Preview
PDF
Download (491Kb) | Preview

Abstract

The primary functions of ventilation systems include the delivery of outdoor air to the occupants, the removal of indoor contaminants and the maintenance of thermal comfort conditions in the occupied zones. The objective of this project is to study a backup ventilation system for individual lecturers’ office space mainly during power failure and when ventilation is not available such as during night. During blackout, the period to repair the power failure takes at least one day. Therefore, the backup ventilation design is important to make sure the lecturers feel comfortable when they are working in their office. The project undertaken looked at the amount of air requirement to the office space in level 3 of Block 17. First, the flow rate of the main blower is determined. Then, the total flow rate at each VAV is compared with the main blower. The total flow rate at each VAV is much lower than the flow rate of the blower. It means that there is a lot of energy wasted during the ventilation process. After comparing these flow rates, the minimum requirement of the ventilation rate is individual lecturer’s office rooms are calculated. The minimum requirement for the ventilation is much lesser than the flow rate supplied by the main blower to each room. Therefore, it will be a lot of energy wasted if we do the backup power supply for the main blower. Based on the results obtained from theoretical and experimental works in this project, the backup ventilation system is feasible to install.

Item Type: Final Year Project
Subject: T Technology > TJ Mechanical engineering and machinery
Divisions: Engineering > Mechanical
Depositing User: Users 5 not found.
Date Deposited: 11 Jan 2012 12:23
Last Modified: 25 Jan 2017 09:43
URI: http://utpedia.utp.edu.my/id/eprint/1485

Actions (login required)

View Item View Item

Document Downloads

More statistics for this item...