Browse content of UTPedia using Year, Subject, Department and Author and Search for required document using Searching facilities included in UTPedia. UTPedia with full text are accessible for all registered users, whereas only the physical information and metadata can be retrieved by public users. UTPedia collaborating and connecting peoples with university’s intellectual works from anywhere.

Disclaimer - Universiti Teknologi PETRONAS shall not be liable for any loss or damage caused by the usage of any information obtained from this web site.Best viewed using Mozilla Firefox 3 or IE 7 with resolution 1024 x 768.

Prediction of Cooling Load of a Glazed Building under Malaysia Weather Conditions

SALEM BASYOAL, OMAR AHMED (2016) Prediction of Cooling Load of a Glazed Building under Malaysia Weather Conditions. IRC, Universiti Teknologi PETRONAS. (Submitted)

[img]
Preview
PDF
Download (2476Kb) | Preview

Abstract

Air conditioning systems in the buildings are essential for the occupants comfort. Good estimation of the cooling load result in a better design of the HVAC system. Moreover, direct solar radiation into the office for buildings that face the east affects the occupants comfort leading to less productivity and might cause illness. This project is aimed to predict the cooling load for a glazed building (Block 16, lecturers’ offices at UTP) under Malaysia weather conditions using cooling load temperature difference (CLTD) method and Hourly Analysis Program. Cooling capacity estimations undertake many variables in order to have optimum air conditioning unit and satisfy the occupant’s needs. Some of these parameters are occupant gains, gains of heat via infiltration, lightening and ventilation and gains through windows and doors. The cooling load results have been compared against the cooling capacity of the system. The project studied the effect of tinted film on glazed wall and the temperature set point. The results show that there is 17.8% overdesign on the cooling capacity of the air handling unit compared to Hourly Analysis Program results.

Item Type: Final Year Project
Academic Subject : Academic Department - Mechanical Engineering - Petroleum
Subject: T Technology > TJ Mechanical engineering and machinery
Divisions: Engineering > Mechanical
Depositing User: Ahmad Suhairi Mohamed Lazim
Date Deposited: 19 Oct 2016 09:16
Last Modified: 25 Jan 2017 09:34
URI: http://utpedia.utp.edu.my/id/eprint/16926

Actions (login required)

View Item View Item

Document Downloads

More statistics for this item...