Browse content of UTPedia using Year, Subject, Department and Author and Search for required document using Searching facilities included in UTPedia. UTPedia with full text are accessible for all registered users, whereas only the physical information and metadata can be retrieved by public users. UTPedia collaborating and connecting peoples with university’s intellectual works from anywhere.

Disclaimer - Universiti Teknologi PETRONAS shall not be liable for any loss or damage caused by the usage of any information obtained from this web site.Best viewed using Mozilla Firefox 3 or IE 7 with resolution 1024 x 768.

Behaviour of Electrical Resistivity with Soil Strength Parameters by Varying the Particle Size Proportion for Mixed Sand and Silt Samples

Haron, Nur Atikah (2016) Behaviour of Electrical Resistivity with Soil Strength Parameters by Varying the Particle Size Proportion for Mixed Sand and Silt Samples. IRC, Universiti Teknologi PETRONAS. (Submitted)

[img] PDF
Download (1301Kb)

Abstract

Geotechnical properties should be precisely identified as it is essential for a successful construction of a structure. Bore hole sampling is known as a conventional method of soil investigation and contributes to reliable determination of soil strength parameters but this method is costly, time consuming and causes soil disturbance. Geophysical methods such as electrical resistivity, is proven to be more efficient because of the non-invasive, non-destructive, rapid and cost-effective aspect. This paper presents the effects of porosity and saturation on electrical resistivity for different particle size proportion. In addition, the behaviour of electrical resistivity with soil strength parameters by varying the particle size proportion for mixed sand and silt samples is also presented. The research involves laboratory test on the mixture of sand and silt with different particle size proportion of; (1) 100% sand, (2) 80% sand, 20% silt, (3) 60% sand, 40% silt, (4) 40% sand, 60% silt, (5) 20% sand, 80% silt, and (6) 100% silt under different moisture content ranging from 15% to 35%.

Item Type: Final Year Project
Academic Subject : Academic Department - Civil Engineering - Water and environment - Water
Subject: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Engineering > Civil
Depositing User: Ahmad Suhairi Mohamed Lazim
Date Deposited: 19 Jan 2017 15:38
Last Modified: 25 Jan 2017 09:34
URI: http://utpedia.utp.edu.my/id/eprint/17156