Browse content of UTPedia using Year, Subject, Department and Author and Search for required document using Searching facilities included in UTPedia. UTPedia with full text are accessible for all registered users, whereas only the physical information and metadata can be retrieved by public users. UTPedia collaborating and connecting peoples with university’s intellectual works from anywhere.

Disclaimer - Universiti Teknologi PETRONAS shall not be liable for any loss or damage caused by the usage of any information obtained from this web site.Best viewed using Mozilla Firefox 3 or IE 7 with resolution 1024 x 768.

Performance Evaluation of Fixed Plate Air To Air Energy Recovery Heat Exchanger in Buildings Air Conditioning System

A/L Ramesh, Potriyan Sivanathan (2016) Performance Evaluation of Fixed Plate Air To Air Energy Recovery Heat Exchanger in Buildings Air Conditioning System. IRC, Universiti Teknologi PETRONAS. (Submitted)

[img] PDF
Restricted to Registered users only

Download (1771Kb)

Abstract

Air mixing system is common in the air conditioning industry. It mixes the two air streams that are the exhaust and incoming fresh air to provide energy saving. Although air filters are present in these systems, certain minute airborne pathogens are able to pass through and continue to circulate in the air conditioned space. This situation allows its inhabitants to be infected especially in places like the operating theater which require 100% clean fresh air. This project aims to provide a solution that does not mix the two air streams, therefore providing clean air. The project is aimed to evaluate the performance of fixed-plate air to air energy recovery heat exchanger for Kuala Lumpur for one year and investigate the energy saving provided by fixed-plate air to air energy recovery heat exchanger compared to the air mixing system to determine the impact of the cooling coil efficiency. The air flow pattern in the heat exchanger is the Z configuration. NTU method is used to determine the sensible and latent effectiveness of the heat exchanger.

Item Type: Final Year Project
Academic Subject : Academic Department - Mechanical Engineering - Materials - Engineering materials - Metals alloys - Fabrication
Subject: T Technology > TJ Mechanical engineering and machinery
Divisions: Engineering > Mechanical
Depositing User: Ahmad Suhairi Mohamed Lazim
Date Deposited: 01 Mar 2017 16:41
Last Modified: 01 Mar 2017 16:41
URI: http://utpedia.utp.edu.my/id/eprint/17249

Actions (login required)

View Item View Item

Document Downloads

More statistics for this item...