Browse content of UTPedia using Year, Subject, Department and Author and Search for required document using Searching facilities included in UTPedia. UTPedia with full text are accessible for all registered users, whereas only the physical information and metadata can be retrieved by public users. UTPedia collaborating and connecting peoples with university’s intellectual works from anywhere.

Disclaimer - Universiti Teknologi PETRONAS shall not be liable for any loss or damage caused by the usage of any information obtained from this web site.Best viewed using Mozilla Firefox 3 or IE 7 with resolution 1024 x 768.

PERFORMANCE ASSESSMENT OF AN OFF DESIGN AIR FINNED COOLER

SAIPUDDIN, NURAMALINA (2016) PERFORMANCE ASSESSMENT OF AN OFF DESIGN AIR FINNED COOLER. IRC, Universiti Teknologi PETRONAS. (Submitted)

[img] PDF
Restricted to Registered users only

Download (809Kb)

Abstract

Nowadays, the usage of air finned cooler are widely being employed in a wide variety of industry including the oil and gas industry. Corrosion and fouling are factor commonly being relate to the degradation of the heat exchanger performance. These lead the engineers to constantly assess the performance of the heat exchanger. A template is being proposed to ease up the assessment of the heat exchanger performance by relating the performance with the off design parameter of the heat exchanger. This template only limited for the air finned cooler heat exchanger that being used in the oil and gas industry. There are two methods being used in order to assess the performance of air finned cooler which are LMTD method and effectiveness-NTU method. These two methods will be used to obtain more accurate result. The off design parameters that will take into consideration are number of plugged pipe which this factor will affect the formula that will be used in the template. The result show that the number of plugged pipe give significant affect to the efficiency of the air finned cooler. The estimation of the life span of the air finned cooler can be approximately estimated by using this template.

Item Type: Final Year Project
Academic Subject : Academic Department - Mechanical Engineering - Petroleum
Subject: T Technology > TJ Mechanical engineering and machinery
Divisions: Engineering > Mechanical
Depositing User: Ahmad Suhairi Mohamed Lazim
Date Deposited: 15 Nov 2017 09:56
Last Modified: 15 Nov 2017 09:56
URI: http://utpedia.utp.edu.my/id/eprint/17372