Browse content of UTPedia using Year, Subject, Department and Author and Search for required document using Searching facilities included in UTPedia. UTPedia with full text are accessible for all registered users, whereas only the physical information and metadata can be retrieved by public users. UTPedia collaborating and connecting peoples with university’s intellectual works from anywhere.

Disclaimer - Universiti Teknologi PETRONAS shall not be liable for any loss or damage caused by the usage of any information obtained from this web site.Best viewed using Mozilla Firefox 3 or IE 7 with resolution 1024 x 768.

Studies on Hydrodynamics in an Ejector Induced Bubble Column

Muhd Amir Zairi Bin Rahim, Muhd Amir Zairi (2011) Studies on Hydrodynamics in an Ejector Induced Bubble Column. Universiti Teknologi Petronas, Sri Iskandar,Tronoh,Perak. (Unpublished)

Full text not available from this repository.

Abstract

Liquid-gas ejector bubble column induced bubble column have been widely used in chemical and biochemical processes especially in oxidation, petroleum refining and fermentation to achieve high interfacial area and high mass transfer. Specifically, the usage of ejector in thermal power station for removal of the boiler bottom ash, in boiling water nuclear reactor it is used to circulate the coolant fluid and in chemical process it is used to inject chemicals into the boiler drums of small, low pressure boilers Bubble column reactors use as a model in this experiment because bubble column are very effective and very simple in design and no mechanical agitator is required. Some other advantages is because they provide uniform bubble size, higher residence time of the gas bubbles and very small amount of gas being dispersed. The unit can also be used to study the characteristic of ejector with both vertical up-flow and down-flow contactors column. The study was analyzed the result findings from the previous experiments which is the relationship between pressure and flow rate using co-current ejector pilot plant. It has been observed that the factor that limits the air entrainment rate is the low discharge coefficient in the liquid inlet line. This experiment is also to observe the relationship of discharge coefficient in the air inlet line to the air entrainment rate.

Item Type: Final Year Project
Subject: T Technology > TP Chemical technology
Divisions: ?? sch_che ??
Depositing User: Users 5 not found.
Date Deposited: 11 Jan 2012 12:23
Last Modified: 19 Jan 2017 15:45
URI: http://utpedia.utp.edu.my/id/eprint/457