Browse content of UTPedia using Year, Subject, Department and Author and Search for required document using Searching facilities included in UTPedia. UTPedia with full text are accessible for all registered users, whereas only the physical information and metadata can be retrieved by public users. UTPedia collaborating and connecting peoples with university’s intellectual works from anywhere.

Disclaimer - Universiti Teknologi PETRONAS shall not be liable for any loss or damage caused by the usage of any information obtained from this web site.Best viewed using Mozilla Firefox 3 or IE 7 with resolution 1024 x 768.

Characteristic of Triplen Harmonics in Low Voltage Network

Mohamad Nasir, Mohamad Hisham (2011) Characteristic of Triplen Harmonics in Low Voltage Network. Universiti Teknologi Petronas. (Unpublished)

[img] PDF
Download (2346Kb)

Abstract

Triplen harmonics study for harmonics produced by non-linear loads and salient pole synchronous generator is very important because their presence have caused communication line interference, damage to neutral earthing resistor etc. The purpose of this project is to study the characteristics of triplen harmonics under balanced/unbalanced resistive/inductive/capacitive loads, different generator neutral earthing resistor values and various transformer winding configurations. Lab scale non-linear load and salient pole synchronous generator is used for the experiment and third harmonic currents are recorded for analysis to represent triplen harmonics currents characteristics. Results from the under balanced load experiment shows that third harmonic current is inversely proportional to load impedance and neutral current is three times the phase current. During unbalanced load condition, the magnitude current is different for each phase and the neutral current is lower than arithmetic sum of phase current due to different phase current magnitude and angle. The phase and neutral third harmonic currents magnitude is inversely proportional to generator NER resistance under balanced load. Transformer winding configurations under balanced load permit third harmonic current flowing through them in accordance to zero sequence network for the transformer apart from higher transformer reactive impedance at third harmonic.

Item Type: Final Year Project
Academic Subject : Academic Department - Electrical And Electronics - Pervasisve Systems - Analogue Electronics - Characterisation
Subject: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Engineering > Electrical and Electronic
Depositing User: Users 2053 not found.
Date Deposited: 27 Sep 2013 11:02
Last Modified: 25 Jan 2017 09:42
URI: http://utpedia.utp.edu.my/id/eprint/6955

Actions (login required)

View Item View Item

Document Downloads

More statistics for this item...