Browse content of UTPedia using Year, Subject, Department and Author and Search for required document using Searching facilities included in UTPedia. UTPedia with full text are accessible for all registered users, whereas only the physical information and metadata can be retrieved by public users. UTPedia collaborating and connecting peoples with university’s intellectual works from anywhere.

Disclaimer - Universiti Teknologi PETRONAS shall not be liable for any loss or damage caused by the usage of any information obtained from this web site.Best viewed using Mozilla Firefox 3 or IE 7 with resolution 1024 x 768.

Implication of Design and Operation on Cooling Load and Energy Cost for Academic Building At UTP

Muhammad Aizuddin Bin Muaz, Muhammad Aizuddin (2008) Implication of Design and Operation on Cooling Load and Energy Cost for Academic Building At UTP. Universiti Teknologi Petronas, Seri Iskandar,Tronoh,Perak. (Unpublished)

[img]
Preview
PDF
Download (6Mb) | Preview

Abstract

Cooling load of a building is very sensitive to the design and the operation of the building itself. Every building from academic complex is unique, in a sense that different designs and operations have different cooling loads. And it is very desirable to determine the cooling load, so the operation of air conditioning system reflects on the building’s specific energy requirement. This will provide a good balance between occupants comfort and the related cost of running it. The objective is to determine the repercussion of design and operation on cooling load and energy cost of Building 17. This project captures air conditioning operation data and translates it to a more understandable output, so that operators understand what is happening with the operation of air conditioning system. The samples data show that the peak operation time is between 3 to 7 pm , with the maximum indoor temperature of 27C and average flowrate of chilled air at 388 l s for that particular time period. It is clear that the operation of the system is heavily influenced by outdoor weather and the electrical appliances inside the building, with several outliers caused by improper actions by users, faulty equipments and system trips.

Item Type: Final Year Project
Subject: T Technology > TJ Mechanical engineering and machinery
Divisions: Engineering > Mechanical
Depositing User: Users 5 not found.
Date Deposited: 11 Jan 2012 12:24
Last Modified: 25 Jan 2017 09:45
URI: http://utpedia.utp.edu.my/id/eprint/928