The main purpose for this report is basically to discuss the preliminary research
done and basic understanding for the chosen topic, which is Energy Efficiency
Audit for Building 13 and Building 14 of Universiti Teknologi PETRONAS.
The objective is to find the level of Building Energy Index (BEI) and the Overall
Thermal Transfer Value (OTTV) for both buildings. The challenges in this project
are to determine the energy consumption for 1 metre square of the building area per
year and also to determine the effect of sunlight on the building envelope. Few
calculations and surveys will be done for the project in order to get the BEI and
OTTV. From the result obtained, the level of BEI and OTTV of both buildings can
be categorized either it is efficient or not. The result of BEI for Building 13 and
Building 14 of UTP are 100.9kWh/m2/Year and 132.7kWh/m2/Year respectively.
While the OTTV for Building 13 and Building 14 are 94.53291 W/m2 and 94.41165
W/m2 respectively. In term of BEI, both building is considered efficient according
to the MS 1525: 2007 standards but for the OTTV, the result is not within the standard.

Item Type: Final Year Project
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Departments / MOR / COE: Engineering > Civil
Depositing User: Users 5 not found.
Date Deposited: 11 Jan 2012 12:24
Last Modified: 25 Jan 2017 09:44
URI: http://utpedia.utp.edu.my/id/eprint/563

Actions (login required)

View Item
View Item