Browse content of UTPedia using Year, Subject, Department and Author and Search for required document using Searching facilities included in UTPedia. UTPedia with full text are accessible for all registered users, whereas only the physical information and metadata can be retrieved by public users. UTPedia collaborating and connecting peoples with university’s intellectual works from anywhere.

Disclaimer - Universiti Teknologi PETRONAS shall not be liable for any loss or damage caused by the usage of any information obtained from this web site.Best viewed using Mozilla Firefox 3 or IE 7 with resolution 1024 x 768.

TEMPERATURE DISTRIBUTION FOR PALM OIL MILL USING IR THERMAL IMAGING

Nur Zaihasra Zahari, Nur Zaihasra Zahari (2012) TEMPERATURE DISTRIBUTION FOR PALM OIL MILL USING IR THERMAL IMAGING. Universiti Teknologi Petronas. (Unpublished)

[img]
Preview
PDF
Download (1610Kb) | Preview

Abstract

This report is an energy audit in an oil palm mill by using the IR (infrared) Thermal Imaging system. The energy audit is to evaluate the energy consumption of the plant (oil palm mill) and management of energy. The efficiency of the energy usage can be evaluated and possible recommendation can be proposed to improve the energy consumption of the plant. This energy audit starts with preliminary research to investigate the main factor of the energy consumption by the plant by doing a walk through energy audit. During this visit to the plant, data is gathered and collected. Using the data obtained the recommendation will be proposed according to the result. The methodology that being used in this project can be classify to four main processes. The first processes are the Building and Utility Data Analysis; Walk through Survey, Baseline for Building Energy Use and Evaluation of Energy Saving Measures. This energy audit is done at FELCRA Nasaruddin Palm Oil Mill, Bota, Perak. This energy audit will focus on two main parts of the plant which are the boiler and the turbine (steam generation) that being used to generate the power needed for the plant operation

Item Type: Final Year Project
Academic Subject : Academic Department - Mechanical Engineering - Materials - Engineering materials - Ceramics - Ceramics processing
Subject: T Technology > TJ Mechanical engineering and machinery
Divisions: Engineering > Mechanical
Depositing User: Users 2053 not found.
Date Deposited: 18 Feb 2013 10:00
Last Modified: 25 Jan 2017 09:40
URI: http://utpedia.utp.edu.my/id/eprint/5602