Browse content of UTPedia using Year, Subject, Department and Author and Search for required document using Searching facilities included in UTPedia. UTPedia with full text are accessible for all registered users, whereas only the physical information and metadata can be retrieved by public users. UTPedia collaborating and connecting peoples with university’s intellectual works from anywhere.

Disclaimer - Universiti Teknologi PETRONAS shall not be liable for any loss or damage caused by the usage of any information obtained from this web site.Best viewed using Mozilla Firefox 3 or IE 7 with resolution 1024 x 768.

A Study of Indoor Air Quality In UTP's Academic Buildings No.18 Level 3

Norsham, Nurufirin (2011) A Study of Indoor Air Quality In UTP's Academic Buildings No.18 Level 3. Universiti Teknologi Petronas. (Unpublished)

[img] PDF
Download (3202Kb)

Abstract

Indoor air quality (IAQ) is a term referring to the air quality within and around buildings and structures, especially as it relates to the health and comfort of building occupants. Research shows that people spend approximately 90 percent of their time indoor, therefore, for many people, the risks to health may be greater due to exposure to air pollution indoors than outdoors. Uuiversiti Teknologi PETRONAS, a place where education takes place, has been build for more than 10 years. In addition, the location is in Malaysia, a hot and humid country. Academic building 18, level 3 is an office for lecturers. The growth of mold, and fungi can be seen at the back of the chairs. This situation indicates that there is something wrong with surrounding environment. Thus, a study is conduct to determine the current status of IAQ inside the building. Next, when the culprit is found, root cause analysis is done by listing all the possible causes and the main reason is selected. Finally, improvement study is done based on how to solve the problem detected before. The temperature, humidity, carbon dioxide (C02) content, ventilation rate and the PMIO content are being recorded. When all the results gains are compared to standard, only PMIO concentration is not complying with it. In the root cause diagram, the four main possible causes for high PMIO concentrations are manpower, machines (which refer to HV AC system), materials and design. After an analysis on all4 main factors, filtration is chosen as the main cause of this problem. In order to perform improvement study, another set of data collection of PMlO on the upstream of the filter is recorded to find its efficiency. From the calculation, the efficiency of current used filter is only 33.91% compared to its original, 80%. Also, the filter has been used for up to 6 years now, since 2006, exceeding its original life cycle, which is I year. Suggestion on changing to new filter is made to over come this problem.

Item Type: Final Year Project
Academic Subject : Academic Department - Mechanical Engineering - Materials - Engineering materials - Polymers - Waste management
Subject: T Technology > TJ Mechanical engineering and machinery
Divisions: Engineering > Mechanical
Depositing User: Users 2053 not found.
Date Deposited: 26 Sep 2013 13:24
Last Modified: 25 Jan 2017 09:42
URI: http://utpedia.utp.edu.my/id/eprint/6812