PARTIAL STROKE TEST OF EMERGENCY SHUTDOWN VALVE - METSO NELES

Sudarman, Siti Farhana Bt (2009) PARTIAL STROKE TEST OF EMERGENCY SHUTDOWN VALVE - METSO NELES. [Final Year Project] (Unpublished)

[thumbnail of Dissertation_Front_page.pdf]
Preview
PDF
Dissertation_Front_page.pdf

Download (96kB)
[thumbnail of Dissertation.pdf]
Preview
PDF
Dissertation.pdf

Download (2MB)
[thumbnail of APPENDIX_dissertation.pdf]
Preview
PDF
APPENDIX_dissertation.pdf

Download (5MB)

Abstract

Potential disasters at an industrial processing plant may include an accident resulting in a massive release of toxic materials, an uncontrollable reactant, a devastating explosion or any combination of the above. All processing plant must be guarded from all potential disaster scenarios. Therefore , emergency shutdown valves has to be sure be operated with fault-free as the valves are kept idle in open position for long periods and are designed to close and keep tight in case of a hazard occur. Regular checking has to be performed in order to guarantee the function of the valves. Emergency Shutdown valves have been tested at unit turnaround, using a Full Stroke Testing and Partial Stroke Testing to demonstrate the performance. The scope of this project is to verify the technology needed for Full Stroke Testing and Partial Stroke Testing in order to ensure the performance of the Emergency Shutdown valve. The testing is simulated by using WideField2 Software (YOKOGAWA) for Full Stroke Test and FieldCare Software (Metso Neles) for Partial Stroke Test. Partial Stroke Testing can be a good complement to Full Stroke Testing as it reduces the required Full Stroke Testing frequency and associated operational impact. Partial Stroke Testing will detect failure of Emergency Shutdown valves without disturbing the process flow. Testing is conducted for sixth times. The valve status and its response to mechanical movement during the test are monitored. Valve performance trend is analyzed after each partial stroke test to find whether there is any potential of valve failure. The result of valve test, pneumatics test, breakdown pressure and load factor are being taken into consideration in analyzing the performance of the emergency shutdown valve.

Item Type: Final Year Project
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Departments / MOR / COE: Engineering > Electrical and Electronic
Depositing User: Users 1278 not found.
Date Deposited: 05 Oct 2012 17:54
Last Modified: 25 Jan 2017 09:43
URI: http://utpedia.utp.edu.my/id/eprint/4085

Actions (login required)

View Item
View Item